Single Wire Line Vertical Flame Test Chamber With Gb18380.1_2001 Standard

China Single Wire Line Vertical Flame Test Chamber With Gb18380.1_2001 Standard supplier

Large Image :  Single Wire Line Vertical Flame Test Chamber With Gb18380.1_2001 Standard

Product Details:

Place of Origin: Guangdong,China (Mainland)
Brand Name: Kinte
Certification: Certificate of conformity of quality management system certification
Model Number: WH-8820C

Payment & Shipping Terms:

Minimum Order Quantity: 1set
Price: customized
Packaging Details: customized
Delivery Time: customized
Supply Ability: customized
Contact Now
Detailed Product Description

Single Wire Line Vertical Flame Test Chamber With Gb18380.1_2001 Standard​

 

 

 

Test standard:
 

In line with China's national standard GB18380.1_2001 "cable in the flame under the conditions

 

of the combustion test Part I: single insulated or vertical cable burning test method", the

 

equivalent use of IEC60332-1.

 

Applicable to the determination of a single plastic line, control, cross-linked, elevators, marine,

 

mining cables and other non-retardant properties. And can do a high self-extinguishing low-

 

smoke halogen-free flame retardant polyolefin insulation materials and 105 ℃ low-smoke

 

halogen-free flame retardant olefin insulation materials vertical burning test.
 

 

Features:
 

The device can automatically ignite and close the test flame, automatic timing, automatic end of

 

the test, high accuracy, easy operation and so on. This equipment consists of control box,

 

combustion box, propane combustion lamp, solenoid valve, high voltage igniter, gas pipe,

 

pressure regulating valve, gas flow meter (propane and air) and signal control line.
 

 

The main parameters:
 

1, vertical combustion box: box size W300xH1200xD450mm;
 

2, gas: the use of high-purity propane gas or liquefied petroleum gas (user-owned);
 

3, be tested wire and cable length: 600 ± 25mm;
 

4, the test wire and cable diameter: conductor diameter greater than 0.8mm or cross-sectional

 

area greater than 0.5mm2;
 

5, the device should be placed in a non-ventilated and temperature (23 ± 10) ℃ environment for

 

testing;
 

6, the flame should be continuous burning of the sample, the flame burning time T Setting range

 

0.1-999.9 (seconds) continuous set;
 

7, the switch can be selected according to actual needs of manual or automatic;
 

8, gas flow range: 0.1-1L / min;
 

9, the air flow range: 0.1-1m3 / h
 

10, burning torch standard power: 1KW;
 

11, the power supply voltage: 220V / 50Hz;